ElectroSeek

All categories

All
  • Battery R&D Equipment
  • Electrosynthesis Reactors
  • Software Tools

More

  • Home
  • Brands
  • Blog
  • Publications
  • Conferences
  • Become a supplier
  • About us
  • Contact us
ElectroSeek
Quote
ElectroSeek
Quote
All productsBrandsBlogPublicationsConferences|Become a supplierAbout usContact us
ElectroSeek

All categories

Browse ElectroSeek product categories.

  • Electrodes and Substrates
    Electrodes and Substrates
    Reference Electrodes
    • Ag/AgCl
    • Calomel (SCE)
    • Hg/HgO
    • Cu/CuSO₄
    • Ag/AgNO3
    • Hg/Hg₂SO₄
    • Other Reference Electrodes
    Counter Electrodes
    • Platinum (Pt)
    • Graphite
    • Gold/Rhodium/Other
    Miniaturized & Screen-Printed Electrodes
    RDE/RRDE Electrodes
    Working Electrodes
    • Glassy Carbon (GC)
    • Platinum (Pt)
    • Gold (Au)
    • Other Metals
    ISE
    • Fluoride (F-)
    • Sodium (Na+)
    • Chloride (Cl-)
    • Calcium (Ca2+)
    • Nitrate (NO3-)
    • Potassium (K+)
    • Other Ions
    Microelectrodes
    • Platinum (Pt)
    • Other Metals
    Substrates & Films
    • FTO/ITO Glass
    • BDD
    • Current collectors
    • CVD Graphene
    • Graphite/Glassy Carbon
    • Metal/Graphene Foams
    • Metal Plates
  • Electrochemical Cells
    Electrochemical Cells
    Standard Electrochemical Cells
    EQCM Cells
    Spectroelectrochemical Cells
    Photoelectrochemical Cells
  • Test Cells & Flow Systems
    Test Cells & Flow Systems
    Cell assemblies
    Electrodialysis Cells
    Electrolysis Cells
    Membranes
    Plate-and-frame electrochemical cells
    Redox Flow Cells
  • Electrochemical Workstations & Test Systems
    Electrochemical Workstations & Test Systems
    Battery Cyclers
    Electrolyzer/Fuel Cell Test Stations
    High-Power EIS
    Low-Current Pot/Galv
    Mid/High-Current Pot/Galv
    PEO
    Impedance Analyzers
  • Battery R&D Equipment
    Battery R&D Equipment
  • Chemicals & Reagents
    Chemicals & Reagents
    Enzymes
    Electrode Inks & Pastes
    Ionophores
    Calibration Solutions
    Electrocatalysts
    Binders
    Redox Mediators
  • Sensors & Meters
    Sensors & Meters
    Conductivity Meters
    Analyzers & Sensors
    pH Meters
  • Electrosynthesis Reactors
    Electrosynthesis Reactors
  • Other accessories and labware
    Other accessories and labware
    Electrode Holders & Clamps
    Miscellaneous Accessories
  • Software Tools
    Software Tools
  1. Home
ElectroSeek

The marketplace for electrochemistry equipment

  • All categories
  • All products
  • Brands
  • Blog
  • Conferences
  • Electrochemistry Wiki
  • Become a supplier
  • About us
  • Contact us

Support and general inquiries:

contact@electroseek.com

Subscribe to our newsletter

© Copyright Electroseek 2026. All rights reserved.

Barcelona, Spain

Privacy Policy
  1. Home
  2. All Categories
  3. Sensors & Meters
  4. Analyzers & Sensors
Loading publications...
Loading reviews...

Get Official Quote

Get pricing and product details from eDAQ.

Customer Reviews

Selected Product
Thumbnail 1Thumbnail 2Thumbnail 3Thumbnail 4Thumbnail 5
Get Quote/Info

Microchip Electrophoresis Kit with Contactless Conductivity Detection

See all products by eDAQ
Price: On request

Description

This microchip electrophoresis system separates and detects charged species on a microfluidic chip, using capacitively coupled contactless conductivity detection (C4D). It includes the contactless conductivity detector, a four-channel high voltage sequencer, a chip platform, microfluidic chips and documented test solutions, with PowerChrom software for data collection and analysis and QuadSequencer software to control the high voltage outputs for floating, gated or pinched injections.

Two versions are available:

  • Electrodes on the chip (ER455): C4D system (ER225), high voltage sequencer, a platform for chips with integrated C4D electrodes, test solutions and a choice of four 45 mm glass chips or two 90 mm chips. The platform has a slit underneath the separation channel so that an optical or fluorescence detector can be used at the same time, reservoirs that hold about 150 µL and a safety interlock that switches off the high voltage when the cover is lifted.
  • Electrodes on the platform (ER490): C4D detector with PowerChrom software (ER815), high voltage sequencer and cables, a platform with built-in C4D electrodes, two Zeonor (cyclic olefin copolymer) chips with a double-T junction, test solutions and a lead wire clamp. Because the electrodes are on the platform, chips with a similar user-developed design can also be used. This version has no safety interlock, which must be provided by the user.

C4D can detect virtually all charged species: inorganic anions and cations, and organic ions such as carboxylic acids, amines, amino acids, peptides, proteins, DNA fragments, antibiotics and many other pharmaceutical compounds. The test solutions contain three cations and three anions (lithium, potassium, sodium, chloride, nitrate and sulphate) in a sample with an acetic acid background electrolyte, to check the separation of both positive and negative ions.

Specifications

General

Applications

Microchip electrophoresis

Measured parameters

Conductivity

Connector Type

SHV

Safety

ER455: interlock on the platform cover (ER490: none, to be provided by the user)

Software

PowerChrom and QuadSequencer (Windows), included

Operating system

Windows

List of Materials

ER455: ER225 C4D system, ER430 HV sequencer, ET225 platform, EC020 test solutions, ET145-4 or ET190-2 chips, ER490: ER815 C4D detector, ER430 HV sequencer, EC230 HV cables, ET121 platform with two ET195-2 chips, EC020 test solutions, ET067 lead wire clamp

Power Supply

Output voltage range

±300 V to ±3 kV per channel

Output current range

Up to 150 µA per channel

Accessories

Maximum electrolyte volume in the reservoir

ER455 platform: approx. 150 µL per reservoir

0.0 out of 5

0 global ratings

5 star
0%
4 star
0%
3 star
0%
2 star
0%
1 star
0%

Verified Identity

Every review undergoes an email verification process to ensure it originates from a verified industry professional.

Verified Purchase

We manually validate "Verified Purchase" claims by cross-referencing with supplier records or identifying the equipment in peer-reviewed scientific publications.

Transparent Publishing

All verified reviews, whether positive or negative, are published without bias as long as they comply with our community guidelines.

No reviews yet. Be the first to share your thoughts!

Write a Review

Share your experience with this product.

Quantity
1

Electroseek will research similar products for you.

References

Help the scientific community by sharing research papers that utilize this equipment.
Contact us to add your research.

Related Products

Istran
EcaMon SaFIA
Electrochemical Analyzers & Sensors

EcaMon SaFIA

Price on request

Istran
EcaFlow 150 GLP
Electrochemical Analyzers & Sensors

EcaFlow 150 GLP

Price on request

Istran
PCA2 Portable Coulometric Analyser
Electrochemical Analyzers & Sensors

PCA2 Portable Coulometric Analyser

Price on request