Price on request
5.0




MedPstat 2.0 Advance is a Portable, Affordable, & Precision Potentiostat/Galvanostat with a wide range of ± 10V, 250 mA. Optimum for electrochemistry research applications. Included is a high-quality dummy cell for learning & calibration applications and lifetime access to free software - MedEplot for PC, data acquisition & plotting.
Instrument Type
Potentiostat/Galvanostat
Weight
0.320 kg
Power supply
100 – 240 VAC, 50/60Hz
Max. channels
1
Operating system
Windows
Instrument architecture
Single-channel
PC connection details
USB
Dimensions
181 × 91.5 × 42 mm
Form factor
Portable
Cell connection
4 electrode, 3 electrode
ADC resolution
16 bit
Ambient temperature when measuring
0 °C to +50 °C
Channel Cable Length
0.8 m
Input impedance
> 10 TΩ
Input Bias Current
1 pA Max
Bandwidth
Up to 10 MHz
Data acquisition rate
1 kHz
Applied potential accuracy
0.1% of the setpoint, 1mV Max
Min. Accuracy voltage (output) / mV
1
Measured potential accuracy
0.1% of the setpoint, 1mV Max
Min. Accuracy voltage (input) / mV
1
Slew rate
45V/µs (No Load)
Min. Voltage resolution (input) / μV
312
Min. Voltage resolution (output) / μV
345
Measured potential resolution
312 µV
Applied potential resolution
345 µV
Potential range
±10 V
Min. Current Accuracy (input) / nA
0.05
Max. current (output) / A
±250 mA
Measured current accuracy
1% of the range, 100 pA max
Current measurement ranges
7 ranges (10 nA to 250 mA)
Measured current resolution
0.03% of range, 3 pA
Applied current resolution
3.45 nA
Min. Current Resolution (output) / pA
3450
Min. Current Resolution (input) / pA
3
EIS configuration
Not available
0 global ratings
Verified Identity
Every review undergoes an email verification process to ensure it originates from a verified industry professional.
Verified Purchase
We manually validate "Verified Purchase" claims by cross-referencing with supplier records or identifying the equipment in peer-reviewed scientific publications.
Transparent Publishing
All verified reviews, whether positive or negative, are published without bias as long as they comply with our community guidelines.
No reviews yet. Be the first to share your thoughts!
Share your experience with this product.
Get pricing and product details from MTX Labs.
Compliance voltage
±15 V
Help the scientific community by sharing research papers that utilize this equipment.
Contact us to add your research.


Price on request
5.0

Price on request

Price on request


Price on request

Price on request


Price on request

Price on request

Price on request