In standard configuration the ISX-3mini is equipped with Sciospec’s IF frontend. Within the measurement range from 100 mHz to 10 MHz (extendable to 40 or 100 MHz) it covers a dynamic range of 300dB (mOhm…TOhm) with a base precision of 0.01%. The two multiplexed 4-electrode MCX measurement ports greatly simplify comparative measurements of two sensors or devices under test.
Price: On request
| Type | Impedance analyzer |
| Form Factor | Benchtop / Lab |
| Channels | ≥ 1, ≥ 32, ≥ 64, ≥ 4, ≥ 2 |
| Cell connection | ≥4 electrode, ≥ 3 electrode |
| PC interface | USB, Ethernet |
| Power supply | 12 V DC (typ.), 15 W (max.), connector DC jack (type: Switchcraft PN: 712A) |
Your request will be sent to Sciospec via email.
| Timing accuracy |
1% accuracy over specified temperature range |
| Operation conditions | temperature range: 0 °C ... 40°C, relative humidity: ≤ 80% (noncondensing), altitude: 0 m ... 3000 m |
| Dimensions - WxDxH / cm | 24.867 x 19.32 x 9.71 (+ 11.56 x 15.63 x 35.3 with MUX32 or + 11.56 x 15.63 x 48.7 with MUX64) |
| Weight / kg | 1 |
| Storage conditions | temperature range: -25 °C … 80 °C, relative humidity: ≤ 80% (noncondensing), The temperature gradient should not exceed 1 K/min to reach operating conditions. |
| Max. Potential range (±) / V | 1 |
| Voltage resolution (output) | < 0.008% |
| Precision of measuremed potential | uncalibrated gain error 1% max., uncalibrated offset error 2%, max. electrometer amplifier input bias current: ±1.5 pA typ. (±50 pA max.), uncalibrated gain error: 0.1% max. for ± 10 mA range, 0.1% max. for ± 100 μA range, 1% max. for ± 1 μA range, 5% max. for ± 10 nA range, uncalibrated offset error 2% max., current amplifier input bias current: ±10 pA typ. (± 1 nA max.) |
| Current range | 4 ranges, ±100 μA to ±10 mA |
| Current Resolution (output) | < 0.008% |
| EIS frequency range | 10 µHz to 10 MHz |
| Max. EIS frequency range / MHz | 10, 40, 100 |
| Min. EIS frequency range / µHz | 100000 |
| Accuracy Contour Plot | See images |
| AC frequency resolution | f < 10 kHz: < 6 mHz, 10 kHz ≤ f ≤ 100 kHz: < 24 mHz, f > 100 kHz: < 117 mHz |
| AC frequency precision | ±100 ppm (@ 25 °C) additional max. ±10 ppm over specified temperature range (e.g., at 0 °C) additional ±5 ppm during first year |
| Potentiostatic EIS Amplitude | 10 mV ... 1 V (peak amplitude) |
| Potentiostatic EIS Amplitude Resolution | 0.1 mV |
| Potentiostatic EIS Precision | ±1% typ. (±8% max.) |
| Galvanostatic EIS Amplitude | 10 μA ... 10 mA (peak amplitude) |
| Galvanostatic EIS Amplitude Resolution | 1 μA |
| Galvanostatic EIS Precision | ±1% typ. (±8% max.) |
| EIS Capability | Yes |